D•Log M

Measure and Document with the Flexible Mobile Data Logger D • Log M

The mobile data logger has a host of benefits, but one of them stands out for others; Its flexibility. The logger can be used in a wide range of applications, and can be connected with a wide range of measuring equipment – For example, sand trap loggers, D-Eye surveillance camera, rain catch, level and flow measurement and even analysis sensor for eg. pH, oxygen measurement etc. In short, the possibilities are endless as all measuring equipment with analogue or digital equipment can be connected.

The logger is equipped with an integrated SIM card (independent of the provider) that ensures data transfer, directly to Danova’s servers via a secure encrypted connection. From there it is possible to access these directly via the web interface, or with SRO / SCADA via API. In addition, it is possible to receive reports on an hourly, day, weekly, monthly or yearly basis. In addition, it is possible to get send text messages, for example. at alarms.

Flexibility also applies in relation to mobility. D-Log M is extremely useful in applications without fixed power due to its long battery life. The low battery consumption is best illustrated by mentioning that when connected to a solar cell, the system is self-sufficient in an overflow building with connection of a  D-Eye camera and an FMR 10 radar – Even in the often gray and cloudy Danish autumn weather.

Read more about the product’s properties, usage and technical data

SKU: 300884 Category: Tag:

Description

Features of D•Log M:

  • Online programming
  • Online secure data
  • Integrated SIM
  • Independent of provider
  • Reports – hour – day – week – year
  • Priority texts
  • No time lag
  • Automatic synchronization
  • Online update
  • Long battery life

Power supply:
2 x Pb battery serial-connected, with a total of 12Ah

Cabinet:
Material: PP / ABS

Weight: 2.36kg (without battery)

Protection: IP67

Size: 266 x 173 x 266mm

Operating temperature:
-20 … + 60 ° C

Humidity:
15 … 90% rh

Storage temperature:
-30 … + 85 ° C

viewing:
2-color LED to indicate operating status

operation:
Button to trigger Aloha transmission mode

Antenna:
FME M

Inputs:
1 x analog for overflow detection

overflow 4 … 20mA: resolution 6.3µA, max. 23.96mA, load 96Ω

1 x digital for overflow detection

digital overflow: max. 32V, min. <1.44V, high> 3.36V, load 8k6

2 x Universal input (analog or digital)

digital overflow: max. 32V, low <1.44V, high> 3.36V, load 8k6
0/4 … 20mA: Resolution 6.3µA, max. 23.96mA, load 96Ω
0 … 2V: resolution 610µV, max. 2.5V, load 10k086
0 … 10V: resolution 7.97mV, max. 32V, load 4k7
PWM: 1 … 99%, max. 100Hz, pulse length min. 1ms, load 8k6
Frequency: 1 … 1000Hz, 8k6
Digital: max. 32V, low <1.44V, high> 3.36V, load 8k6
Day counter: heart rate min. 1ms, load 8k6
Interval counter: heart rate min. 1ms, load 8k6

Outputs:
3 x 24V sensor supply (max. 100mA)
2 x adjustable 24V sensor supply (max. 20mA)

Condition:

Ext heating time
digital
Frequency: range 1 … 1000Hz, normalized consumption 50%
Pulse / min

1 x sensor supply:

Output voltage (can be selected via configuration parameter):

15V at I out = 45mA
23.3V at I out = 45mA

Condition:

Ext heating time
digital

System time:
Hardware Real-Time watch, with independent backup battery and automatic time synchronization with the server

Internal sensors:
Internal temperature
Measuring range: -20 … + 60 ° C
Solution: 0.1 ° C

Humidity in cabinet
Measuring range: 0 … 100% rH
Solution: 0.1% rH

USB Interface:
1 x Mini-B USB 2.0 for connecting to a PC. For Communication with the Stationary Overflow Monitoring System, the DeviceConfig configuration program must be installed on the PC.

Data storage:
Internal flash memory for up to 30,832 measurement cycles

Data type:
f32 (32Bit floating point)

Data transmission:
2G / 3G Penta-Band Modem:

2G GPRS 850MHz / 1900MHz
2G GPRS 900MHz / 1800MHz
UMTS B1, B2, B4, B5, B6, B8, B19

SIM:
The Stationary Overflow Monitoring System is equipped with an integrated SIM chip.

Rechargeable battery 12V / 15 Ah
Charger for D-Log M batteries
antennas
Input connector
Brackets
User setup on Danova’s server: 24/7 Data access
5 years of data / 3 MB per month

When ordering options – please call 66149323

Order before 10 am: Day to day delivery

The product in use

There is an increasing problem with overflows from the jointly drained drainage systems. The number of incidents in which rainy outflows are affecting watercourses, including organic matter, must be closely monitored for the purpose of … (Further reading)

Related articles

Professional contribution to DR’s article on effluent discharge at overflow

With reference to DR’s article by Line Jenvall on July 23, 2019 (DR article), we feel in DANOVA, a professional need to contribute a follow-up comment .. (Further reading)

Ved at bruge hjemmesiden accepterer du brugen af cookies og vores persondatapolitik mere information

Cookie indstillingerne på denne hjemmeside er aktiveret for at give dig den bedste oplevelse. Hvis du fortsætter med at bruge hjemmesiden uden at ændre dine cookie indstillinger eller du klikker Accepter herunder, betragtes dette som din accept

Luk